ATI Chlorine Dioxide Gas Concentration Meter "Model F12"

Measuring gas: chlorine dioxide, standards: 2ppm / 20ppm / 200ppm / 5ppm, etc.

The "F12 type" is a chlorine dioxide gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "ozone gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Chlorine Dioxide ■ Sensor Model: 00-1004 / 00-1005 / 00-1359 / 00-1425 ■ Minimum Range: 0-1ppm / 0-5ppm / 0-200ppm / 0-1ppm ■ Maximum Range: 0-5ppm / 0-200ppm / 0-1000ppm / 0-5ppm ■ Standard: 2ppm / 20ppm / 200ppm / 5ppm ■ Auto Test Generator: 00-1538 / 00-1538 / - / 00-1538 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI Formaldehyde Gas Concentration Meter "Model F12"

Measurable formaldehyde gas! Used in various places such as plants and laboratories.

The "F12 model" is a formaldehyde gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "ozone gas concentration meters," and "chlorine dioxide gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Formaldehyde ■ Sensor Model: 00-1040 / 00-1349 ■ Minimum Range: 0-20 ppm / 0-500 ppm ■ Maximum Range: 0-200 ppm / 0-2000 ppm ■ Standard: 20 ppm / 1000 ppm ■ Auto Test Generator: 00-1539 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI EOG Gas Concentration Meter "Model F12"

This is an EOG gas concentration meter used in various places such as plants and laboratories.

The "F12 model" is an EOG gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "ozone gas concentration meters," "chlorine dioxide gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Ethylene Oxide ■ Sensor Model: 00-1039 ■ Minimum Range: 0–20 ppm ■ Maximum Range: 0–200 ppm ■ Standard: 20 ppm ■ Auto Test Generator: 00-1539 *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Hydrogen Peroxide Gas Concentration Meter (New Isomon-2) [ATI]

With one unit, measurement and control of low concentration safe allowable concentration and high concentration sterilization and disinfection gas concentration (0-2000 ppm).

NewIsomon-2 can measure hydrogen peroxide gas over a wide range with a single unit. For example, it can measure high concentration levels (0-2000ppm) during the sterilization process of hydrogen peroxide gas in pharmaceutical and food factories, as well as low concentration levels (0-100ppm) after aeration, all with one device. 【Features】 - It has a built-in suction pump, allowing for quick concentration measurements. - It comes standard with a 4-20mA output and alarm output necessary for control. - It can measure concentrations within the range of 0-2000ppm with high precision. *Demo units are available. Please feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI Peracetic Acid (PAA) Gas Concentration Meter "Model F12"

It is possible to continuously measure peracetic acid (PAA) gas. It allows for the verification of permissible concentration for safety confirmation and concentration checks during decontamination.

The "F12 model" is a peracetic acid gas concentration meter. It is a fixed installation type, and with various measurement ranges and options available, it can accommodate a wide range of specifications. In addition to this product, we also offer a rich selection of sensors for hydrogen peroxide, peracetic acid, chlorine dioxide, ozone, EOG gas, and more. 【Sensor Selection Table】 ■ Measured Gas: Peracetic Acid / Peracetic Acid / Acetic Acid ■ Sensor Model: 00-1704 / 00-1705 / 00-1045 ■ Minimum Range: 0-1ppm / 0-10ppm / 0-100ppm ■ Maximum Range: 0-5ppm / 0-100ppm / 0-500ppm ■ Standard: 2ppm / 20ppm / 100ppm *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

ATI Ozone Gas Concentration Meter "Model F12"

Measuring gases: Ozone, maximum range: 0–2000 ppb / 0–5 ppm / 0–200 ppm / 0–1000 ppm, etc.

The "F12 model" is an ozone gas concentration meter. The gas detectors from ATI that we handle can measure over 30 types of toxic gases and oxygen. They are used in various locations such as plants and laboratories. Additionally, we also offer "EOG gas concentration meters," "chlorine dioxide gas concentration meters," and "formaldehyde gas concentration meters." 【Sensor Selection Table】 ■ Measured Gas: Ozone ■ Sensor Model: 00-1163 / 00-1008 / 00-1009 / 00-1358 ■ Minimum Range: 0–500 ppb / 0–1 ppm / 0–5 ppm / 0–200 ppm ■ Maximum Range: 0–2000 ppb / 0–5 ppm / 0–200 ppm / 0–1000 ppm ■ Standard: 0–1000 ppb / 2 ppm / 20 ppm / 1000 ppm ■ Auto Test Generator: 00-1538 * For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration